Headpower Rooftop Package Units are designed and manufactured to offer the all-in-one solutions, the units are ideal for residential, commercial and industrial applications and are available in nominal cooling capacity from 3Ton to 55Ton. Quality design and construction make air-cooled rooftop package units with hermetic scroll compressors the preferred applications and easy installation and maintenance.

2.the main specification of 240000 Btuh Rooftop air conditioners
WK05 | WK06 | WK08 | WK10 | WK12 | WK15 | WK18 | WK20 | WK25 | |||||||||||||
Unit Performance | Cooling capacity | kW | 13 | 15.6 | 21 | 26 | 31.5 | 39 | 46.8 | 54 | 65 | ||||||||||
Heafrig capadty (heatpurp) | kW | 13.6 | 16.3 | 22.5 | 28 | 33 | 42 | 50 | 58 | 70 | |||||||||||
Aid Electric Heafrig Capacity | KW | 9 | 12 | 15 | 21 | 25 | 32 | 36 | 45 | 45 | |||||||||||
Air Volume | m3/h | 3000 | 3600 | 4800 | 5800 | 7000 | 8500 | 9800 | 11000 | 12600 | |||||||||||
ESP | Pa | 150 | 500 | 150 | 500 | 150 | 500 | 200 | 600 | 250 | 600 | 250 | 600 | 300 | 650 | 300 | 650 | 300 | 650 | ||
Fan PCwer | KW | 0.75 | 1.5 | 1.1 | 2.2 | 1.1 | 3 | 1.5 | 3 | 1.5 | 3 | 2.2 | 4 | 3 | 5.5 | 3 | 7.5 | 4 | 7.5 | ||
Temp.Control Precision | 18-30 ±1 | ||||||||||||||||||||
Humidity Control Precision | 50 percent -70 percent ±5 percent RH | ||||||||||||||||||||
Power Supply | 3N-50HZ 380V | ||||||||||||||||||||
Cooling System | Cooling Capacity | Mediim | R22/R407C | ||||||||||||||||||
Expansion Way | Thermal Expansion Valve | ||||||||||||||||||||
Compressor | Type | Hermetic Scroll | |||||||||||||||||||
Nominal Power | R22 | 4 | 4.7 | 6 | 8 | 9.5 | 12 | 14.1 | 16 | 19 | |||||||||||
R407C | 4.1 | 4.8 | 6.2 | 8.2 | 9.7 | 12.3 | 14.4 | 16.4 | 19.4 | ||||||||||||
Fvaporafrr | Type | Copper tubes with aluminum fins | |||||||||||||||||||
Fin Type | Two-way slotted aluminum fin | ||||||||||||||||||||
Type | Copper tubes with aluminum fins | ||||||||||||||||||||
Condenser | Fin Type | Corrugated aluminum fin | |||||||||||||||||||
Fan System | Condensrg Fn | lype DrwMode | Ultra-low-Noise Wide Blade Axial / Direct Drive | ||||||||||||||||||
Max. outdoor temperatire | A5 degree | ||||||||||||||||||||
Pc«er(kw) | 0.28 | 0.28 | 0.55 | 0.75 | 1.1 | 1.1 | 1.1 | 1.5 | 2.2 | ||||||||||||
SA Fan | Type | Ultra-low-noise double-inlet centrifugal unit | |||||||||||||||||||
Drive Mode | Belt Drive | ||||||||||||||||||||
the sections examples of 240000 btuh rooftop air conditioners
Project introduction//240000 Btuh Rooftop Air Conditioners
Single cooling, electric heating, heat pump, de-humidification, full fresh-air, clean, constant temperature and humidity etc.
Cooling, heating, humidification, de-humidification, air purification, noise elimination, heat recycle, multi-level control of air quantity and cooling capacity, etc.







Popüler Etiketler: 240000 btuh rooftop air conditioners, China, manufacturers, customized, quotation, low price, made in China

